ABB IRC5 Control Cabinet DSQC661 Power Supply Fault Repair: Troubleshooting Host Computer Failure to Boot and Communication Interruption
When a fault occurs in the DSQC661 power supply unit within the ABB IRC5 control cabinet, it may lead to the main computer failing to boot, the teach pendant screen going black, control module communication interruption, system repeated restarts, or the robot being unable to be enabled. This article focuses on the DSQC661 3HAC026253-001, introducing methods for input power supply, output load, connection wiring, internal circuitry, and post-repair verification under load.

In this article
ABB IRC5 Control Cabinet DSQC661 Power Supply Fault Repair: Troubleshooting Host Failure to Start and Communication Interruption
ABB IRC5 control cabinets require multiple groups of stable power supplies to power the main computer, teach pendant, I/O modules, communication boards, and control circuits. DSQC661 is one of the common power supply units in the IRC5 system, with the common material number 3HAC026253-001.
When the DSQC661 output is abnormal, the control cabinet may still have main power input, but the main computer, teach pendant, or some control modules may fail to operate normally. On-site personnel can easily misdiagnose this as a fault with the main board, teach pendant, or communication module.
On-site diagnostic conclusions:
If the control cabinet has no power at all, first check the external incoming lines and main switch. If the control cabinet has power but the main computer, teach pendant, and multiple control modules are simultaneously abnormal, focus on checking the DSQC661 input, output, and its loads. If only one module is offline, first check that module and its corresponding wiring.
Applicability:
This article primarily applies to ABB IRC5 control systems configured with the DSQC661 3HAC026253-001 power supply unit. Different control cabinet versions and hardware configurations may use different power supply units. The complete material number of the original module and electrical drawings must be verified before repair or replacement.
1. The Role of DSQC661 in the IRC5 Control Cabinet
DSQC661 is responsible for providing stable power to the relevant low-voltage control circuits within the IRC5 control system.
Its operating status may affect:
- IRC5 main computer startup.
- Teach pendant power supply and communication.
- Control boards and communication modules.
- I/O system operation.
- Control cabinet internal relays and auxiliary circuits.
- Data communication between the controller and the robot body.
- System startup and servo enable conditions.
When the power output is unstable, different modules may exhibit seemingly unrelated alarms, such as teach pendant disconnection, I/O loss, and main computer restart.
2. Common DSQC661 Fault Manifestations
On-site, the following may occur:
- The system does not start normally after the control cabinet main switch is turned on.
- Main computer indicator lights are off.
- Teach pendant screen is black or cannot connect to the controller.
- IRC5 restarts repeatedly during the startup process.
- Multiple communication modules go offline simultaneously.
- All I/O signals are suddenly lost.
- The controller crashes after running for a period of time.
- The system can start when cold but fails after warming up.
- DSQC661 has no normal output.
- The power supply module emits abnormal sounds or odors.
- The module and terminals show signs of heating, discoloration, or burning.
If multiple low-voltage control modules are simultaneously abnormal, priority should be given to checking the common power supply, rather than separately replacing the host, I/O board, and teach pendant.
3. Information to Record Before Repair
Before starting the inspection, record the following:
- Complete ABB robot model.
- IRC5 control cabinet model.
- RobotWare software version.
- Complete DSQC661 material number.
- Actual performance of the control cabinet after power-on.
- Main computer and module indicator light status.
- Whether the teach pendant has backlight or a startup screen.
- Complete alarm codes and alarm text.
- Whether the fault occurs in a cold or warm state.
- Recent occurrences of power outages, surges, or liquid ingress into the control cabinet.
- Whether the power supply, host, or communication modules have been replaced.
- Whether the system backup is complete.
It is recommended to take photos of the overall control cabinet, the DSQC661 nameplate, wiring status, and indicator lights of all related modules.
4. How to Check if the Control Cabinet Has No Power at All
If the control cabinet shows no response at all after the main switch is turned on, first check the power supply chain before the DSQC661.
Key inspection points include:
- Whether the external power supply is normal.
- Whether the control cabinet incoming line voltage meets requirements.
- Whether the main switch is properly closed.
- Whether circuit breakers and protective devices have tripped.
- Whether incoming line terminals are loose or burnt.
- Whether the control transformer and preceding power supplies are normal.
- Whether there are abnormalities in the emergency stop and external power supply circuits.
- Whether the DSQC661 input terminal receives normal power.
If the DSQC661 input terminal has no power, the fault is typically located in the preceding power supply or protection circuit, and the power supply module should not be disassembled first.
5. How to Diagnose Normal Input but No Output
If the DSQC661 input is normal but the relevant output is missing, further check:
- Whether the module output terminals are loose.
- Whether the output connectors are burnt.
- Whether the module has entered a protection state.
- Whether there is a short circuit or overload on the output side.
- Whether the module's internal fuses and protection circuits are abnormal.
- Whether the internal switching power supply has started.
- Whether the module exhibits abnormal temperature rise.
- Whether the indicator light status is normal.
Do not only measure the no-load output. Some power supply modules show normal voltage under no-load conditions, but experience a drop or enter protection when connected to the actual load.
6. Distinguishing Between Output Short Circuit and Power Supply Module Fault
No output from the DSQC661 does not necessarily mean the module itself is damaged. A short circuit on the output side boards or wiring can also cause the power supply to enter protection.
Abnormal output load may originate from:
- Internal short circuit in the main computer.
- I/O board fault.
- Abnormal power circuit in the communication module.
- Short circuit in the teach pendant wiring.
- Insulation damage to control cabinet cables.
- Liquid ingress or contamination in connectors.
- Incorrect terminal wiring.
- Overload caused by external devices connected to the control power supply.
Check the loads in sections according to the electrical drawings to confirm whether the power supply immediately drops or enters protection after connecting a particular load.
7. Common Internal Fault Locations in DSQC661
After confirming the fault is within the power supply unit itself, typically check:
- Input protection circuit.
- Rectification and filtering section.
- Startup circuit.
- Switching power supply power devices.
- High-frequency transformer and related connections.
- Output rectification and filtering circuit.
- Voltage feedback and voltage regulation circuit.
- Overcurrent and overtemperature protection circuits.
- Electrolytic capacitor condition.
- Connectors and high-current solder joints.
- Heat sinks and thermal conduction structures.
Capacitor aging may cause increased output ripple, difficulty starting, and hot restart. Solder joint cracking may cause intermittent power loss after the control cabinet is subjected to vibration.
8. Common manifestations of capacitor aging
Internal filter capacitors in the DSQC661, which are exposed to high-temperature environments for extended periods, may gradually degrade in performance.
Common manifestations include:
- Difficulty starting when cold.
- Occasional successful start after multiple power-on attempts.
- Automatic restart after running for a period of time.
- Significant fluctuations in output voltage.
- Voltage drop when load increases.
- Abnormal noise inside the module.
- Bulging top or leakage at the bottom of capacitors.
Normal capacitor appearance does not necessarily indicate normal capacitance, equivalent series resistance, and filtering capability; further confirmation through professional testing is required.
9. Impact of control cabinet temperature on power supply
Poor heat dissipation in the IRC5 control cabinet can accelerate the aging of internal capacitors, power components, and solder joints in the power supply.
Inspection items include:
- Whether the filter mat is clogged.
- Whether the control cabinet fan is rotating normally.
- Whether the air intake and exhaust vents are obstructed.
- Whether dust has accumulated around the DSQC661.
- Whether the control cabinet door and sealing strips are intact.
- Whether the ambient temperature is too high.
- Whether there are other abnormally heating components near the module.
If the equipment starts normally when cold but restarts after running for several hours, focus should be on checking module temperature rise, fans, and output load.
10. Why power supply failure can cause communication interruption
Communication modules, the main computer, and I/O boards require stable control power. When voltage drops or ripple increases, it may cause:
- Sudden restart of the main computer.
- Disconnection between the teach pendant and the controller.
- I/O modules going offline.
- Fieldbus devices dropping offline.
- Multiple boards simultaneously reporting communication alarms.
- Frequent network connection drops and recoveries.
- RobotWare startup failure.
If multiple communication devices drop offline at approximately the same time, first check the common control power supply, grounding, and main computer status.
11. Troubleshooting sequence for main computer startup failure
When the main computer fails to start, check in the following order:
Step one: Confirm that external power supply to the control cabinet is normal.
Step two: Check the input and output status of the DSQC661.
Step three: Check the main computer power connector.
Step four: Observe the main computer indicator lights and fan.
Step five: Check storage media and internal connections.
Step six: Check display, network, and teach pendant communication.
Step seven: Confirm whether the output voltage is stable under actual load.
If the main computer power supply is unstable, replacing the main computer usually does not solve the root problem.
12. Relationship between teach pendant black screen and power supply failure
A black screen on the teach pendant may originate from the teach pendant itself, cables, control cabinet interface, or control power supply.
Key inspection points include:
- Whether the teach pendant backlight is completely off.
- Whether the control cabinet main computer has started.
- Whether the teach pendant cable is damaged.
- Whether the control cabinet interface has normal power supply.
- Whether the DSQC661 and related power outputs are stable.
- Whether the status changes when moving the teach pendant cable.
If the main computer, I/O, and teach pendant are all abnormal simultaneously, priority should be given to checking the common power supply. If only the teach pendant has a black screen, first check the teach pendant and its connecting lines.
13. Grounding and power quality inspection
Abnormal on-site power quality may cause the DSQC661 to protect or become damaged.
Inspection items include:
- Whether the input voltage is stable.
- Whether there is phase loss or abnormal phase sequence.
- Whether grounding is reliable.
- Whether significant fluctuations occur when high-power equipment starts.
- Whether welding equipment causes interference.
- Whether control cabinet shielding and grounding connections are complete.
- Records of lightning strikes, surges, or frequent power outages.
- Whether the control cabinet shares power with unsuitable loads.
If multiple control cabinets restart at the same time, priority should be given to checking the workshop's common power supply, rather than replacing power modules one by one.
14. Determining direction based on fault phenomena
【Control cabinet completely without power】
Priority checks: External power supply, main switch, circuit breakers, and upstream power.
【Control cabinet has power but main computer does not start】
Priority checks: DSQC661 output, main computer power connection, and load short circuit.
【Teach pendant and multiple modules go offline simultaneously】
Priority checks: Common control power supply, main computer, and communication power supply.
【Difficulty starting when cold, more prone to failure when hot】
Priority checks: Internal capacitors, solder joints, heat dissipation, and module temperature rise.
【Power supply protection triggered after connecting a specific board】
Priority checks: Whether that board, its wiring, or connectors are short-circuited.
【Control cabinet restarts after being subjected to vibration】
Priority checks: Terminals, connectors, fuse holders, and high-current solder joints.
15. DSQC661 repair process
Step one: Record fault phenomena, alarms, and indicator light status.
Step two: Record complete material information for the IRC5 and DSQC661.
Step three: Back up the system, programs, and parameters.
Step four: Check external power supply and upstream protection circuits.
Step five: Test the input status of the DSQC661.
Step six: Check output under no-load and load conditions.
Step seven: Troubleshoot the output side load in sections.
Step eight: Test internal power supply and protection circuits of the module.
Step nine: Repair or replace confirmed damaged components.
Step ten: Complete load, hot-running, and full machine operation tests.
16. What to verify before replacing the DSQC661
Before replacing the power supply unit, confirm:
- The complete name of the DSQC661.
- The material number 3HAC026253-001 and its version.
- The original module's hardware revision information.
- The IRC5 control cabinet model.
- Input and output interfaces.
- Installation location and mounting method.
- Original module wiring status.
- Control cabinet load configuration.
Do not select the module based solely on the "DSQC661" name. Before disassembly, photograph the nameplate and wiring, and label the connectors.
17. Post-repair module testing
After DSQC661 repair, the following should be performed:
- Input protection check.
- No-load output test.
- Output test under different loads.
- Output stability and ripple check.
- Overcurrent protection function check.
- Temperature rise and heat dissipation test.
- Long-term operation test under load.
- Connector and solder joint re-inspection.
Normal no-load voltage does not prove the module is repaired; loaded and hot-running conditions must be verified.
18. Post-repair whole-machine verification
After reinstallation into the IRC5 control cabinet, check:
- Module and connectors are securely installed.
- No tools are left inside the control cabinet.
- Grounding and protective devices are restored to normal.
- DSQC661 indicator status is normal.
- Main computer can start up stably.
- Teach pendant can connect normally.
- I/O and communication modules are all online.
- RobotWare can enter the system normally.
- Robot servos can be enabled normally.
- Low-speed operation of each axis is stable.
- Control cabinet does not restart after continuous operation.
- Power module temperature rise is within normal state.
Only when the host, communication, I/O, and robot operation are all normal can the power fault handling be confirmed as complete.
19. Common issues
Is no output from DSQC661 always due to module damage?
Not necessarily. Short circuits on the output side board, cables, or connectors can also cause the power supply to enter protection.
Does a black screen on the teach pendant require replacing DSQC661?
First check the main computer, teach pendant cables, and control cabinet interfaces. Only after confirming an abnormality in the common control power supply should further testing of DSQC661 be performed.
Why does the control cabinet automatically restart after running for a period?
It may be related to aging power capacitors, module temperature rise, poor heat dissipation, or abnormal output load.
The module output is normal under no-load, why does it fail to start after installation?
It could be due to reduced load capacity, or a short circuit or overload in one of the loads within the control cabinet.
20. Daily maintenance recommendations
- Regularly clean the control cabinet filter cotton and air ducts.
- Check the operating status of control cabinet fans.
- Record the times of abnormal control cabinet restarts.
- Regularly inspect power terminals and connectors.
- Avoid moisture and dust accumulation inside the control cabinet.
- Check power status after surges or power outages.
- Save system and RobotWare backups.
- Do not repeatedly switch on to test a control cabinet with a short circuit.
21. Summary
When an ABB IRC5 control cabinet experiences issues such as the host failing to start, a black screen on the teach pendant, or multiple communication modules going offline simultaneously, the common control power supply should be checked first.
When DSQC661 input is normal but output is abnormal, it is also necessary to distinguish between internal power module faults and short circuits on the output side load. After repair, no-load, loaded, hot-running, and IRC5 whole-machine operation tests must be performed.
Technical content reference: ABB IRC5 control system, DSQC661 3HAC026253-001 power unit documentation, and industrial robot control cabinet repair experience.
Repair consultation
If repair is needed for ABB IRC5 control cabinet, DSQC661 3HAC026253-001 power unit, host failure to start, or communication interruption faults, please provide robot model, control cabinet model, module nameplate, indicator status, and fault video.
Industrial robot repair hotline: +86 18122009539
Contact repair engineer: +86 18122009539
Need a part or repair assessment?
Share the robot model, part number, fault details and destination country with our team.
Contact our team ↗