ZhonghengbiaoZHB
Robot parts and independent repair support. From Foshan, China, to your next inquiry. Talk to us ›
ABB Robot Repair

How to Repair ABB IRB 6640 Axis 2 Reducer Jitter? From Backlash Detection to Re-commissioning Verification

When the ABB IRB 6640 Axis 2 exhibits jitter, abnormal noise, positioning deviation, or following error, the fault may originate from increased reducer backlash, bearing wear, abnormal balancing mechanism, incorrect tool load, or unstable servo feedback. This article, targeting the ABB IRB 6640 paired with an IRC5 controller, introduces the diagnostic sequence for Axis 2 reducer faults, on-site inspection methods, repair precautions, and the re-commissioning verification process.

How to Repair ABB IRB 6640 Axis 2 Reducer Jitter? From Backlash Detection to Re-commissioning Verification
In this article

How to Repair ABB IRB 6640 Axis 2 Reducer Jitter? From Backlash Detection to Re-commissioning Verification
ABB IRB 6640 is a heavy-duty six-axis industrial robot, commonly used for handling, welding, and large workpiece operations. Axis 2 needs to bear the combined load of the upper arm, forearm, wrist, and end effector. Therefore, after long-term operation, frequent acceleration/deceleration, or collisions, issues such as increased reducer backlash, operational jitter, abnormal noise, positioning deviation, and following error may occur.
On-site Diagnostic Conclusion:
When the ABB IRB 6640 Axis 2 exhibits directional reversal jitter or fixed position deviation, first check the tool load, external interference, balancing mechanism, and mechanical connections, then inspect the reducer, servo motor, encoder feedback, and IRC5 drive channel. Do not replace the drive unit solely based on a "following error" alarm.
Scope of Application:
This article is applicable to ABB IRB 6640 robots and their IRC5 control systems. Specific reducer part numbers, calibration requirements, and parameter ranges should be based on the robot body nameplate and the corresponding version of the ABB maintenance manual.
1. Common Manifestations of Axis 2 Reducer Faults
When abnormalities occur in the Axis 2 mechanical parts, the following manifestations are typical:
- Significant jitter during forward/reverse directional reversal.
- Periodic abnormal noise during low-speed operation.
- Arm rebound after the robot stops.
- Positioning deviation during repeated positioning at the same location.
- Axis 2 motor temperature higher than other axes.
- Oil leakage or abnormal temperature rise near the reducer.
- Normal operation under no load, fault worsens under load.
- Controller displays overcurrent, overload, or following error alarms.
If alarms consistently correspond to Axis 2 and are related to directional reversal, load, or specific postures, mechanical inspection should be prioritized.
2. Information to Record Before Repair
It is recommended to save the following before disassembly:
- Robot model and body serial number.
- IRC5 controller model and system version.
- Axis 2 alarm code and alarm text.
- Robot posture when the alarm occurred.
- Direction of movement, speed, and load status.
- Tool weight, center of gravity, and inertia parameters.
- Whether the fault occurred after a collision or program modification.
- Photos of the Axis 2 motor, reducer, and cables.
- Backups of system, program, calibration, and load data.
Recording "Axis 2 jitters when reversing from negative to positive angle" is more helpful for subsequent diagnosis than simply recording "Axis 2 abnormal."
3. First, Exclude Tool Load and Mechanical Interference
Axis 2 faults are not necessarily from the reducer. The following factors can increase Axis 2 load:
- Tool weight exceeding the set value.
- Incorrect tool center of gravity or inertia parameters.
- Workpiece clamping offset.
- Interference between fixture, workpiece, and peripheral equipment.
- Welding torch cables, air hoses, or cable carriers pulling on the arm.
- Abnormal operation of the balancing mechanism.
If tools or fixtures have been replaced, the load data should be re-verified. Incorrect load parameters cause the motor to output higher torque during acceleration and deceleration phases and may trigger following error or overcurrent alarms.
4. How to Determine Abnormal Reducer Backlash
When reducer backlash increases, the robot is prone to deviation during directional reversal, stopping, and repeated positioning.
Focus on observing:
- Whether the resistance during Axis 2 forward and reverse operation is different.
- Whether there is impact or noticeable jitter at the moment of directional reversal.
- Whether the positioning result differs when reaching the same position from different directions.
- Whether arm rebound occurs after stopping.
- Whether the reducer has abnormal noise, oil leakage, or abnormal temperature rise.
- Whether the fault is concentrated at a specific mechanical angle.
If backlash, abnormal noise, and temperature rise coexist, professional inspection of the reducer and bearings should be arranged. When involving Axis 2 support and disassembly/assembly, appropriate support, lifting, and positioning tools meeting requirements must be used.
5. Servo Motor and Encoder Inspection
The Axis 2 servo motor may experience winding abnormalities, brake not fully released, bearing damage, or poor power cable contact.
Inspection items include:
- Whether the motor is abnormally hot.
- Presence of humming, friction, or impact sounds.
- Whether power cables and connectors are burnt.
- Whether the brake releases normally.
- Whether encoder feedback cables are damaged, stretched, or crushed.
- Whether connector pins are oxidized, bent, or retracted.
If the fault only occurs in specific postures, priority should be given to checking whether the IRB 6640 body cables are excessively bent in that posture.
6. IRC5 Drive Alarm Diagnostic Approach
- Alarm immediately upon power-up or servo enable: Check power lines, motor, encoder, and drive channel.
- Normal at low speed, alarm at high speed: Check load, mechanical resistance, and drive unit cooling.
- Jitter during directional reversal: Check reducer backlash, mechanical connections, and load parameters.
- Alarm after running for a period: Check motor temperature rise, reducer temperature rise, and control cabinet cooling.
- Multiple axes alarm simultaneously: Check control power supply, common communication, and controller status.
The specific meaning of alarm codes varies with controller and RobotWare versions; refer to the corresponding ABB manual.
7. Repair and Re-commissioning Process
Step 1: Confirm the faulty axis number and save alarm and parameter data.
Step 2: Exclude tool load, fixture interference, and external cable pulling.
Step 3: Inspect Axis 2 reducer, bearings, balancing mechanism, and mechanical connections.
Step 4: Inspect the servo motor, brake, power lines, and encoder feedback.
Step 5: Inspect the IRC5 drive module, axis computer, and cooling system.
Step 6: Repair or replace faulty components based on inspection results.
Step 7: Confirm installation, lubrication, wiring, and calibration status.
Step 8: Complete low-speed single-axis, no-load coordinated motion, load operation, and process sample testing.
After repair, do not use only "alarm disappearance" as the completion criterion; also confirm that positioning accuracy, operational sound, axis temperature, and production quality have returned to normal.
8. Frequently Asked Questions
Question 1: Does Axis 2 following error always mean reducer damage?
Not necessarily. The motor, encoder, cables, load parameters, brake, and drive unit can all cause following errors.
Question 2: Is recalibration required after replacing the reducer?
Whether calibration is needed depends on the scope of disassembly/assembly, mechanical position changes, and controller prompts; confirm according to the ABB manual for the corresponding model.
Question 3: No-load test is normal, but alarm persists under load. What to do?
Re-check tool weight, center of gravity, inertia, balancing mechanism, and external cables. Do not simply increase the operating speed further.
Question 4: How to submit repair information?
It is recommended to provide the robot body nameplate, IRC5 control cabinet model, alarm code, faulty axis number, fault video, and on-site photos.
9. Summary
ABB IRB 6640 Axis 2 jitter repair should follow the sequence of "first record, then exclude external factors, then inspect mechanical and servo systems." Directional reversal jitter, fixed position deviation, and abnormal temperature rise require more attention to the reducer, bearings, and balancing mechanism; power-up alarms and feedback abnormalities should prompt checks on the motor, encoder, cables, and IRC5 drive channel.
Technical Review: Zhongheng Biao Industrial Robot Maintenance Engineer
Reference Materials: ABB IRB 6640 Product Manual, IRC5 System Manual, and On-site Maintenance Records
Content Update Time: September 2026
Repair Consultation
If you need to repair ABB IRB 6640 Axis 2, reducer, servo motor, or IRC5 control system, please provide the robot model, controller model, alarm code, faulty axis number, and on-site photos or videos.
Industrial Robot Repair Hotline: +86 18122009539
Contact Repair Engineer: +86 18122009539
Suggested Related Articles:
ABB Robot Following Error Alarm Repair
ABB Robot Servo Motor Encoder Alarm Repair
ABB Robot Zero Point and Positioning Accuracy Check After Collision
ABB IRC5 Control Cabinet Drive Unit Fault Repair

Need a part or repair assessment?

Share the robot model, part number, fault details and destination country with our team.

Contact our team ↗
← All robot insights

Discuss your requirements

Send the model, part number, quantity and destination country, or describe the equipment fault. Our team will review your sourcing or repair requirements.

Contact Us