Industrial Robot Daily Inspection: A Practical Guide to Anomaly Recording and Efficient Communication
Effective daily inspection is not only the foundation of preventive maintenance but also the key to early fault detection. This article focuses on standardized methods for recording anomaly information during inspections and provides a set of standardized processes for efficient and accurate communication with maintenance engineers, aiming to shorten fault diagnosis time and improve overall equipment effectiveness.

In this article
01Introduction
The stable operation of industrial robots is the cornerstone for ensuring the continuity of automated production lines. As the first line of defense in preventive maintenance, the core value of daily inspection lies in the early detection of potential anomalies. However, many field operators often face the dilemma of "seeing a problem but not being able to describe it clearly" during inspections, leading to inefficient communication with maintenance engineers and delaying the optimal time for fault handling. This article will systematically explore how to standardize the recording of inspection anomalies and establish an efficient communication mechanism.
02I. Key Observation Points and Anomaly Identification in Daily Inspection
Before making inspection records, it is first necessary to clarify "what to look for" and "how to look." Inspection should not be a mere formality but should focus on subtle changes that may indicate faults.
### 1. Body and Mechanical Structure
* Abnormal Vibration and Noise: During low-speed operation of each robot axis, listen for abnormal friction sounds, impact sounds, or periodic vibrations. Record the specific axis number where the anomaly occurs (e.g., J3 axis) and the approximate operating speed range.
* Oil Leaks and Stains: Check for oil stains, water stains, or grease seepage near the seals of each axis reducer, gearbox, and air hose connections. Record the specific location of the leak and the color and viscosity of the contaminant (e.g., thin, paste-like).
* Bolts and Structural Components: Visually inspect key areas (e.g., base, arm connections) for signs of loose, corroded, or peeling paint on fastening bolts.
### 2. Electrical and Control Systems
* Cables and Connectors: Check the robot body cables and teach pendant cables for wear, broken insulation, or pinch marks. Inspect connector plugs for looseness, signs of arcing/burning, or water ingress.
* Control Cabinet Status: Observe whether the internal fans are operating normally, if the filter mats are clogged, and if the indicator lights on each module are in their normal states (e.g., power, safety, drive modules). Record any abnormal indicator light colors (e.g., constant red, flashing) or if they are off.
* Teach Pendant and Operation Panel: Check if the key feel is normal and if the touch screen has scratches, display ghosting, or localized unresponsiveness.
### 3. Operational Performance and Trajectory
* Positioning Accuracy and Repeatability: When running standard programs, observe whether the end effector can accurately and smoothly reach preset points, and if there is noticeable settling vibration or overshoot.
* Operating Speed and Current: Pay attention during program execution to see if any axis motors exhibit abnormal acceleration or deceleration lag, or if the motor current values displayed on the controller show an abnormal increasing trend under unchanged load conditions.
03II. Standardized Methods for Recording Anomaly Information
Clear and accurate records are the prerequisite for efficient communication. It is recommended to use the "5W1H" principle for structured recording.
### 1. Record Template Elements
* Equipment Identification (What/Which): Clearly record the robot brand (e.g., ABB, Fanuc, KUKA), specific model, asset number, or production line station number.
* Time and Operating Conditions (When): Record the specific date and time when the anomaly was first discovered, and the task the robot was performing at that time (e.g., "welding door at station 5", "palletizing empty load test").
* Phenomenon Description (What Happened): This is the core of the record. It must be objective and specific, avoiding subjective judgments.
* Good Example: "When J2 axis rotates from -30 degrees to +15 degrees at a speed setting of 20%, a continuous 'clicking' metal friction sound can be heard, which increases with speed. The surface temperature of the axis feels noticeably higher than that of the J1 axis."
* Poor Example: "J2 axis has abnormal noise, might be broken."
* Location and Frequency (Where/How Often): Precisely describe the mechanical location where the anomaly occurs (e.g., "lower cover seam of axis 3 reducer") or the electrical point (e.g., "pin 5 of connector X32"). Also state whether the anomaly is persistent, intermittent, or only appears during specific motion sequences.
* Initial Actions (How): Record the safety measures already taken by the inspector (e.g., "warning tag posted", "foreman notified") and any simple verification actions performed (e.g., "phenomenon persists after controller restart", "noise reappears when manually moving the axis"). Do not attempt any in-depth operations involving opening electrical cabinets, removing protective covers, or modifying parameters.
### 2. Auxiliary Recording Tools
* Photography and Videography: A clear photo or a short video is often worth a thousand words. Ensure the frame is focused and includes equipment identification and a close-up of the anomaly (e.g., leak point, damaged cable). When recording video, you can verbally describe the anomaly and operating conditions simultaneously.
* Marking and Schematic Diagrams: Use arrows or circles to directly mark the anomaly location on equipment photos or simple diagrams for clarity.
04III. Efficient Communication Process with Maintenance Engineers
Based on standardized records, a standardized communication loop can be constructed.
### 1. Preparation Before Communication
Organize the above structured records (text, pictures, video) into a concise report. If the control system has historical alarm records or operation logs, take screenshots and save them, noting the time range.
### 2. Key Points During Communication
* Stick to Facts, Avoid Speculation: Directly state the recorded phenomena, not personal diagnostic conclusions (e.g., say "motor current reached 120% of rated value under load", not "I think the motor is weak").
* Provide Complete Background: Proactively inform about the equipment's recent maintenance history (e.g., "J3 axis gear oil was changed last week"), process changes, or related peripheral equipment conditions. This information is crucial for fault tracing.
* Clarify Communication Purpose: Clearly express the need, for example: "Need your assistance in assessing the severity of this noise and recommendations for next steps," or "Based on the symptoms, does it require immediate shutdown for inspection?"
### 3. Follow-up After Communication
Record the maintenance engineer's preliminary assessment, recommended next steps (e.g., "continue monitoring", "schedule shutdown inspection for a specific time"), and the agreed-upon time for the next communication. Add the key information from this communication to the inspection record or maintenance request form to create a traceable archive.
05IV. Safety Reminders and Summary
Important Safety Note: Daily inspection and anomaly recording work must be performed by trained and qualified personnel only after the equipment is safely stopped and energy isolation is completed (e.g., lockout/tagout). Any actions involving opening control cabinets, removing mechanical guards, or operating the teach pendant in maintenance mode must be performed by authorized maintenance engineers. Recording personnel must not attempt to reset unknown alarms, bypass safety signals, or adjust critical operating parameters.
In summary, the daily inspection of industrial robots is a task that requires both meticulousness and standardization. By establishing systematic methods for observation, recording, and communication, the "eyes and ears" of operators can be effectively extended to become the "frontline sensors" of the maintenance team, enabling a shift from reactive repair to proactive prevention, ultimately enhancing the reliability and operational efficiency of the entire production system.
Need a part or repair assessment?
Share the robot model, part number, fault details and destination country with our team.
Contact our team ↗